AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT
Los medidores de glucosa se utilizan para ayudar al profesional de la salud a monitorear y detectar alteraciones de la glucosa sanguínea (GS). El objetivo fue comparar la técnica de HemoCue (HC) versus glucosa oxidasa (GOx) para la medición de GS utilizando 368 mediciones de GS por ambos métodos. Se...
Tallennettuna:
Päätekijät: | , , , , , , |
---|---|
Aineistotyyppi: | Online |
Kieli: | eng |
Julkaistu: |
Universidad de Sonora
2018
|
Linkit: | https://biotecnia.unison.mx/index.php/biotecnia/article/view/809 |
Tagit: |
Lisää tagi
Ei tageja, Lisää ensimmäinen tagi!
|
id |
biotecnia-article-809 |
---|---|
record_format |
ojs |
spelling |
biotecnia-article-8092022-05-31T17:21:57Z AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT Gallegos Aguilar, Ana Cristina Esparza Romero, Julian Hernández Martínez, Héctor Hiram Urquídez Romero, Rene Rascón Careaga, Antonio Bolado Martínez, Enrique Díaz Zavala, Rolando Giovanni Glucosa sanguínea HemoCue Glucosa Oxidasa Los medidores de glucosa se utilizan para ayudar al profesional de la salud a monitorear y detectar alteraciones de la glucosa sanguínea (GS). El objetivo fue comparar la técnica de HemoCue (HC) versus glucosa oxidasa (GOx) para la medición de GS utilizando 368 mediciones de GS por ambos métodos. Se utilizaron gráficos de Bland & Altman, prueba de t-pareada y regresión lineal para su comparación. Se encontró concordancia entre los métodos en la mayoría de los niveles de glucosa, excepto a concentraciones de glucosa ≥ 6.993 mmol/L. El analizador de glucosa HC es bueno para su uso en estudios de campo ya que es técnicamente fácil y requiere muy poco mantenimiento; sin embargo, se recomienda tener especial cuidado con aquellas personas cuyos valores de glucosa están dentro del límite del diagnóstico de diabetes ya que, con el método HC, existe el riesgo de clasificar erróneamente a las personas que ya tienen diabetes como no diabéticas. Por lo tanto, dada la importancia de conocer los valores reales de los niveles de glucosa en este grupo de personas para un diagnóstico preciso, se recomienda considerar un análisis posterior con el método GOx para corroborar el resultado. Universidad de Sonora 2018-12-23 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Original peer-reviewed articles Artículos originales evaluados por pares application/pdf https://biotecnia.unison.mx/index.php/biotecnia/article/view/809 10.18633/biotecnia.v21i1.809 Biotecnia; Vol. 21 No. 1 (2019): Enero-Abril; 22-28 Biotecnia; Vol. 21 Núm. 1 (2019): Enero-Abril; 22-28 1665-1456 1665-1456 eng https://biotecnia.unison.mx/index.php/biotecnia/article/view/809/296 Derechos de autor 2018 Biotecnia |
institution |
Biotecnia |
collection |
OJS |
language |
eng |
format |
Online |
author |
Gallegos Aguilar, Ana Cristina Esparza Romero, Julian Hernández Martínez, Héctor Hiram Urquídez Romero, Rene Rascón Careaga, Antonio Bolado Martínez, Enrique Díaz Zavala, Rolando Giovanni |
spellingShingle |
Gallegos Aguilar, Ana Cristina Esparza Romero, Julian Hernández Martínez, Héctor Hiram Urquídez Romero, Rene Rascón Careaga, Antonio Bolado Martínez, Enrique Díaz Zavala, Rolando Giovanni AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT |
author_facet |
Gallegos Aguilar, Ana Cristina Esparza Romero, Julian Hernández Martínez, Héctor Hiram Urquídez Romero, Rene Rascón Careaga, Antonio Bolado Martínez, Enrique Díaz Zavala, Rolando Giovanni |
author_sort |
Gallegos Aguilar, Ana Cristina |
title |
AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT |
title_short |
AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT |
title_full |
AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT |
title_fullStr |
AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT |
title_full_unstemmed |
AGREEMENT BETWEEN HEMOCUE AND GLUCOSE OXIDASE METHODS FOR BLOOD GLUCOSE MEASUREMENT IN A FIELD WORK STUDY OF DIABETES: THE COMCAAC PROJECT |
title_sort |
agreement between hemocue and glucose oxidase methods for blood glucose measurement in a field work study of diabetes: the comcaac project |
description |
Los medidores de glucosa se utilizan para ayudar al profesional de la salud a monitorear y detectar alteraciones de la glucosa sanguínea (GS). El objetivo fue comparar la técnica de HemoCue (HC) versus glucosa oxidasa (GOx) para la medición de GS utilizando 368 mediciones de GS por ambos métodos. Se utilizaron gráficos de Bland & Altman, prueba de t-pareada y regresión lineal para su comparación. Se encontró concordancia entre los métodos en la mayoría de los niveles de glucosa, excepto a concentraciones de glucosa ≥ 6.993 mmol/L. El analizador de glucosa HC es bueno para su uso en estudios de campo ya que es técnicamente fácil y requiere muy poco mantenimiento; sin embargo, se recomienda tener especial cuidado con aquellas personas cuyos valores de glucosa están dentro del límite del diagnóstico de diabetes ya que, con el método HC, existe el riesgo de clasificar erróneamente a las personas que ya tienen diabetes como no diabéticas. Por lo tanto, dada la importancia de conocer los valores reales de los niveles de glucosa en este grupo de personas para un diagnóstico preciso, se recomienda considerar un análisis posterior con el método GOx para corroborar el resultado. |
publisher |
Universidad de Sonora |
publishDate |
2018 |
url |
https://biotecnia.unison.mx/index.php/biotecnia/article/view/809 |
work_keys_str_mv |
AT gallegosaguilaranacristina agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject AT esparzaromerojulian agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject AT hernandezmartinezhectorhiram agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject AT urquidezromerorene agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject AT rasconcareagaantonio agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject AT boladomartinezenrique agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject AT diazzavalarolandogiovanni agreementbetweenhemocueandglucoseoxidasemethodsforbloodglucosemeasurementinafieldworkstudyofdiabetesthecomcaacproject |
_version_ |
1756584799019991040 |